Spray Booth Filters

Inlet, Exhaust, Pre-filters and Ceiling Filters for Spraybooth/Ovens

Pre-Filter Specifications

Av. Arrestance93%
Initial Arrestance87%
Air Volume5,400 m³/hr/m²
Initial Resistance37 Pa
Final Recommended Resistance250 Pa
Maximum Operating Humidity100%
Dust Holding Capacity635 g/m²
Filter Depth20 mm
ClassificationEurovent G4
Flame ResistanceDIN 53437 F1/K1
Airbus ATS-1000.001

Paint Stop Spray Booth Filter Specifications

2″ PAINT STOP4″ PAINT STOP
Average paint arrestance
95-98 %98-99 %
Air volume2500-6300 m3/hr/m22500-6300 m3/hr/m2
Initial resistance7-40 Pa14-60 Pa
Paint holding capacity at 80 Pa and 0.7 m/s3500-4700 g/m23900-5900 g/m2
Filter depth (nominal)50-65 mm95-110 m
Flame resistanceDIN 53438 F1/K1DIN 53438 F1/K1

Ceiling Filters

Ceiling filters are available on a roll or as pre-cut pads.

The high performance fine filters are manufactured entirely from bonded fibres. The fibres are build up progressively from the base to form a high density matrix.

The media construction ensures high initial arrestance and exceptional dust holding capacity at low pressure resistance, creating the ultimate combination of service life, performance and economy. A special adhesive agent is applied to the fibres during manufacture in order to enhance dust holding capacity, optimising arrestance and provide complete protection against mitigation caused by excess vibration. The addition of an open mesh scrim provides even greater stability and prevents dust being released when the filters are soiled.

Ceiling Filter Specifications

Average arrestance
98%
“Average efficiency
”52%
Air volume2700 m³/hr/m²
Initial resistance65 Pa
Final recommended resistance450 Pa
Temperature resistance100 °C
Maximum operating humidity100 % RH
Dust holding capacity385 g/m2
Filter depth20 mm
ClassificationEurovent EN779 2012 M5
Flame resistanceDIN 53438 F1/K1